TBRE101 30 Hz – 100 KHz RE101 Loop Antenna
The TBRE101 is a passive receiving loop antenna used in MIL-STD-461G RE101 testing to measure radiated emissions from electronic equipment and subsystems, including electrical cable interfaces for defense applications.
The TBRE101 is used to measure low frequency magnetic field emissions 7cm from all sides of the DUT. The test covers the frequency range of 30 Hz to 100 KHz. Section 5.17 of the MIL -STD-461G specifies the test setup and measurement procedure.
The TBRE101 consists of a 13.3 cm diameter coil with 36 turns of 7 strand 41 AWG Litz wire inside a shield. The DC resistance of the loop winding is 10 ohms. The loop receives magnetic field radiation normal to the contained plane and creates a voltage signal proportional to the intensity of the B -field/H-field radiation at the loop's output port.
A TekBox TBCCP1-2K70 coaxial RF current monitoring probe (transducer) with a flat transfer impedance of 0 dBΩ (1V/A) from 9 kHz to 30 MHz when loaded with 50Ω is an optional accessory for calibration purposes.
SPECIFICATION
- Antenna Type: Receiving Loop
- Frequency range: 30 Hz–100 KHz (usable frequency range: 10 Hz-1 MHz)
- Standards: MIL-STD-461G / RE101
- Loop Diameter: 13.3cm
- Loop construction: 36 turns of 7 strand 41 AWG Litz wire
- DC resistance of the loop coil: 10Ω (Nominal)
- Self inductance of the loop coil: 385 µH
- Output connector: N-female, 50 Ω
- Antenna conversion factor: Within ±3 dB compared to the theoretical validation factor for standard RE101 loop in MIL-STD-461G
- Mechanical Dimensions: L x W x H: 10.62 cm x 15.2 cm x 19.1 cm (4.18” x 5.98” x 7.52”)
- Weight: 0.5 kg (1.1 lbs)
DOCUMENTATION
Part Number | Description |
TBRS101-TX | Radiating loop for generating magnetic fields in the range of 30 Hz to 100 KHZ |
ТВCCP1-2K70 | Coaxial RF current monitoring probe for measuring the injected current into the radiating loop |
TBMR-110M | 1Hz - 110 MHz measurement receiver, CISPR 16 and MIL-STD-461 |